Clark Tanks phone Clark Tanks 1800 88 79 79
Clark Tanks home Clark Tanks rainwater tanks Clark Tanks farm products Clark Tanks site preparation Clark Tanks delivery contact Clark Tanks

Site preparation and maintenance for a Clark polyethylene tank

Clark Tanks site preparation

Download Recommended Site Installation Sheet

  1. Ensure the location of the tank is level, stable ground which has uniform compaction (free of soft spots). Do not locate large water tanks close to retaining walls or embankments without first consulting a professional engineer to ensure the ground is capable of supporting the weight of the full tank.
     
  2. Ensure the surface of the site is free from sharp objects or stones and is compacted.
     
  3. Spread a thin layer (approx. 20-40mm) of 3mm metal/crusher dust – bedding sand can be used but is prone to erosion – evenly over the level ground, at least 500mm more than the diameter of the tank. Once it is compacted and level you may then place the tank directly on top of this material. To assist with reducing soil erosion, back fill to first rib.
     
  4. Specifications for slab for 10,300 gal and 8,000 gal tanks:
    • Slab must be at least 150mm bigger then the base diameter of the tank
    • Slab must be at least 150mm thick with 2 layers of F82 mesh 75mm apart and a thickening of 200mm wide and 200mm deep with Y16 reo bar at the bottom of the thickening around the edge of the slab
    • Slab must be 32 mpa concrete mix
    • Ensure all plumbing from the outlets is well supported and cannot be knocked.
     
  5. Ensure the metal/crusher dust is contained under the tank at all times and cannot be washed away. This can be achieved by diverting all run-off water away from the site and retaining the metal/crusher dust with some form of retaining structure e.g. cement strip, rocks or sleepers.
     
  6. A flexible coupling must be fitted to each outlet to validate the guarantee.
     
  7. For stand applications, ensure the stand is designed to carry the weight of a full tank. Support slats on the stand should be no further than 20mm apart.
     
  8. For concrete slab applications, the slab must be at least 15cm wider than the base diameter of the tank and at least 15cm thick with 2 layers of F82 mesh 75mm apart and a thickness of 20cm wide and 20cm deep, with Y16 reo bar at the bottom of the thickening around the edge of the slab and a 32 mpa concrete mix. If in doubt of soil stability, you must consult a civil engineer and they will design the slab accordingly.
     
  9. Ensure all plumbing from the outlet is well supported and cannot be knocked (A flexible coupling ensures no strain is applied to the outlet).
     
  10. Ensure all overflows are plumbed away from the tank site to reduce the possibility of erosion.
    Your Clark Polyethylene Tank requires very little maintenance, simply check the site for any erosion and remove leaves and other debris from the roof, inlet and overflow at regular intervals.